Main
Unit
| MM-60R |
Multifunction
Meter w/Standard Accessories. |
Optional
equipment and accessories for MM-60R
| 6949070K
(HM-30R, CM-30R, MM-30R) |
Ambient
Temperature and humidity sensor |
| 6949080K
(HM-30R, CM-30R, MM-30R) |
Remote
switch for auto hold, data memory, and print key |
| EPS-R |
External
printer unit w/cable, 60mm wide |
| 118B603 |
Connection
cable to external printer |
| P000119 |
60mm
wide printer Paper, 20 roll/pk |
| ORD00001 |
Ink
Ribbon Cartridge for External Printer, 1 pc |
| G-LOG2 |
Data
Acquisition Software for PC to CSV format. (Requires 118B604 RS-232C
cable, 2m) |
| R-LOG |
USB/LAN
data collection software for PC to CSV format. |
| ES-1G
(HM-30R, MM-60R) |
Electrode
Selector for up to 5 pH, ORP, or Ion electrodes |
| ES-1GC
(CM-30R, MM-60R) |
Conductivity
Cell Selector for up to 5 Cond. Cells |
| ES-1GC
(MM-60R) |
Electrode
Selector for up to 5 DO electrodes |
| AH-1G |
Automatic
Electrode Calibration Unit |
| AC-1V
(HM-30R, CM-30R. MM-60R) |
Control
Box allows for upper and lower pH limits to be controlled by 100 V
relay for reagent pump/pH control.. |
| OGC00002 |
RS-232
Conection Cable, 2m. |
| PC-1G
(HM-25R, HM-30R, MM-60R) |
pH
Checker / Calibration unit |
| EC-1G
(CM-25R, CM-30R, MM-60R) |
Electrical
Conductivity Check test plug. |
|
TC-1G (HM, CM, or MM R-series) |
Temperature
Checker test plug. |
| OIF00001 |
Electrode
Stand Set |
| OIB00001 |
Electrode
Holder (Electrode Attachment Not included) |
| OIB00004
- OIB00008 |
Electrode
Attachment, G/04, J/05, Ion/06, DP/07, N/08 |
|
Stirrers
assemblies: |
| ST-15 |
Magnetic
stirrer |
| S-HLD-S |
Electrode
Holder |
| S-STD-S |
Electrode
Stand |
| ST-20A |
Overhead
Rod type stirrer and electrode holder |
|
Automatic
Samplers: |
| TTT-510-12 |
Automatic
turntable unit, 12 samples.(uses 200ml tall beakers) |
| TTT-510-18 |
Automatic
turntable unit, 18 samples.(uses 100ml tall beakers) |
| TTT-510-32 |
Automatic
turntable unit, 32 samples.(uses 50ml tall beakers) |
| TTT-510-60 |
Automatic
turntable unit, 60 samples.(uses 20ml tall beakers) |
| OGC00001 |
G
Series meter to TTT-510 Connection Cable, 1.5M(std) |
| P000020 |
Waste
Water Valve |
| P000021 |
Waste
Water Valve, electric magnetic |
| P000022 |
Non-Aqueous
pump for reagent delivery |
| P000032 |
Propeller
Stirrer motor |
|
Additional
electode holders, connection cables, extensions, beakers, and accessories
also available. |
pH Electrodes
GST-5741C
(General Purpose)
(Standard with HM-30R)
|
Strong
pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Min. 1ml
sample volume. Calibration Memory function |
| ELP-031
(Organic Solvent) |
Strong
pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Moveable
sleeve junction. Min. 3ml sample volume. Calibration Memory function |
| ELP-032
(Precision pH)) |
Strong
pH Glass Electrode, 0-14pH, 0-60C (3 in 1; pH, Ref, Temp.) Fixed sleeve
junction. Min. 2ml sample volume. Calibration Memory function |
| GST-5723S
(Precision Trace Volume) |
pH
Glass Electrode, 0-11pH, 0-60C (3 in 1; pH, Ref, Temp.)
1ml sample volume. Calibration Memory function |
| GST-5724C
(Insertion/spear type, Neutralization) |
pH
Glass Electrode, 0-12pH, 0-60C (3 in 1; pH, Ref, Temp.)
0.5ml sample volume. Calibration Memory function |
| ELP-035
(Trace sample volume) |
5mm
Diam. Strong pH Glass Electrode, 0-13pH, 0-100C (3 in 1; pH, Ref,
Temp.) 0.5ml sample volume. Calibration Memory function |
| ELP-036
(Ultra trace Volume) |
3mm
Diam. Strong pH Glass Electrode, 0-13pH, 0-60C (3 in 1; pH, Ref, Temp.)
0.3ml sample volume. Calibration Memory function |
| ELP-037
(Test Tube use) |
8mm
Diam., long body, Strong pH Glass Electrode, 0-13pH, 0-100C (3 in
1; pH, Ref, Temp.) 0.5ml sample volume. Calibration Memory function |
| ELP-038
(Ultra trace, narrow test tube use, NMR tube, etc.) |
3mm
Diam., long body, Strong pH Glass Electrode, 0-13pH, 0-60C (3 in 1;
pH, Ref, Temp.) 0.3ml sample volume. Calibration Memory function |
| GST-5720C
(Flow Thru monitoring) |
pH
Glass Electrode 0-12 pH, 0-60C (3 in 1; pH, Ref, Temp.)
250ul cell volume for continuous monitoring. |
| ELP-039
(Strong Alkali Use) |
pH
Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.)
1ml sample volume. Calibration Memory function |
| ELP-040
(Hydrofluoric Acid Use) |
pH
Glass Electrode, 2-12pH, 0-50C (3 in 1; pH, Ref, Temp.)
30ml sample volume. Plastic body with replaceable glass tip. Calibration
Memory function |
GST-5731C
(General Purpose)
(Standard with HM-25R) |
Strong
pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Min. 1ml
sample volume. |
| PST-5721C
(General Purpose ORP) (Reduction-Oxidation) |
ORP
Electropde. 0-100C. 3 in 1 ORP Platinum Electrode, (mV, Ref, Temp.)
1ml samlpe volume. Calibration Memory function. |
Dissolved
Oxygen Electrodes
OE-270AA
Immersion / throw-in use
|
DO: 0-20mg/L, 0-200% / 0-500% saturation, 0-50C, Electrolyte R-9 (OBG00007),
Uses OCC00001 membrane set (High conc. use OCC00002). Cable Length:
3m standard. (5 and 11m available).
Calibration memory function. |
OE-570BA
Immersion / throw-in use
No flow use |
DO:
0-20mg/L, 0-200% / 0-500% saturation, 0-50C, Electrolyte R-9 (OBG00007),
Uses OCC00023 membrane set (High conc. use OCC00024). Cable Length:
3m standard. (5 and 11m available).
Calibration memory function. |
|
OE-470BA
Egg Bottle
or BOD bottle use
suitable for No flow use
|
DO:
0-20mg/L, 0-200% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses
OCC00022 membrane set. Cable Length: 1m standard. Calibration memory
function. |
OE-470AA
Egg Bottle or BOD bottle use
Built in stirrer |
DO:
0-20mg/L, 0-200% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses
OCC00022 membrane set. Cable Length: 1m standard. Built in stirrer.
Calibration memory function. |
Conductivity
Cells
CT-57101B
(General Purpose)
Immersion type
|
EC:
100uS/m to 10S/m (1uS/cm to 100ms/cm), 0-100C., Cell const. 100E10-1m,
Min. 4ml sample volume. Diam 14mmx26mm. Built in temp. Calibration
Memory function |
CT-57101C
(Low Range Cond.)
Immersion type |
EC:
5uS/m to 1S/m (0.05uS/cm to 10ms/cm), 0-100C., Cell const. 10E10-1m,
Min. 6ml sample volume. Diam 14mmx42mm. Built in temp. Calibration
Memory function |
|
CT-57101A (High
Range Cond.)
Immersion type
|
EC:
1mS/m to 100S/m (10uS/cm to 1S/cm), 0-100C., Cell const. 1000E10-1m,
Min. 39ml sample volume. Diam 36mmx38mm. Built in temp. Calibration
Memory function |
CT-87101B
(General Purpose)
Flow Thru type |
EC:
100uS/m to 10S/m (1uS/cm to 100ms/cm), 0-100C., Cell const. 100E10-1m,
Cell volume is 4ml. Built in temp. Calibration Memory function |
CT-27111D
(Pure Water Use)
Flow Thru type |
EC:
5uS/m to 20S/m (0.05uS/cm to 200ms/cm), 0-80C., Cell const. 1E10-1m,
Cell volume is 8ml. Built in temp. Calibration Memory function. Note:
a seperate flow cell is required. CEF-22A (PP), or CEF-23A (SUS316) |
|
CT-87101C (Low
Range Cond.)
Flow Thru type
|
EC:
5uS/m to 1S/m (0.05uS/cm to 10ms/cm), 0-100C., Cell const. 10E10-1m,
Cell volume is15ml. Built in temp. Calibration Memory function |
CT-87102A
(High Range Cond.)
Flow Thru type
|
EC:
10mS/m to 100S/m (100uS/cm to 1ms/cm), 0-100C., Cell const. 2000E10-1m,
Cell volume is 1ml. Built in temp. Calibration Memory function. Note:
a rubber syringe septum or pump tube is required. |
Specific
Ion Electrodes:
| Electrode |
Measuring
Range |
pH
range/temp |
Influence
of co-existent ions (selective coefficient) |
Ion
Tip replacement |
Membrane |
Sodium
ion, combination
NA-2011 |
2.3
- 23K mg/l Na+ |
10-11
pH / 60C |
Mg+2,
Ca+2, NH4+, Li+, K+=10E3 |
NA-100B |
Glass
membrane |
|
Potassium ion,
combination
K-2031
|
0.39
- 39K mg/l k+ |
5-6
pH / 50C |
H+=10E2,
NH4+=3x10E2, Na+=2x10E3, Li=10E4 |
K-300B |
Liquid
Membrane |
Calcium
ion, combination
CA-2031 |
0.4
- 40K mg/l Ca+2 |
5-6
pH / 50C |
Pb+2=33,
Zn+2=45, Mn+2=1.7x10E2, Cd+2=8.8x10E2, Fe+2=1.2x10E3, Mg+2=1.8x10E3,
Ba+2=1.9x10E3, Cu+2=2.7x10E3, Ni+2=9.0x10E3 |
CA-300 |
Liquid
Membrane |
Fluoride
ion, combination
F-2021 |
0.019
- 19K mg/l F- |
5-6
pH / 50C |
OH-=10E1,
HPO4-2, HCO3-=10E3(pH7-8), Cl-, Br-, I-, NO3-, SO4-2,S2O3-2=10E5 |
F-200 |
Solid
Membrane |
Chloride
ion, combination
CL-2021 |
1
- 35K mg/l Cl- |
5-6
pH / 50C |
S-2
must be absent, CN-, I-=10E5, Br-, S2SO3-2+10E-2, F-,NO3-, SO4-2,
CO3-2, PO4-3=10E3 |
CL-200B |
Solid
Membrane |
Cyanide
ion, combination
CN-2021 |
0.003
- 26 mg/l CN- |
12-13
pH / 50C |
S-2
must be absent, I-=10E-1, S2O3-2=10E1, Br-=10E3, NO3-, SO4-2, PO4-3=10E4,
CO3-2, Cl, F-=10E5(at 10 mol/l) |
CN-200B |
Solid
Membrane |
Nitrate
ion, combination
N-2031 |
0.62
-62K mg/l NO3- |
5-6
pH / 50C |
I-=7x10E-2,
Br-=1.7, NO2-=4.5, Cl-=2x10, CH3COO=1.2x10E2, SO4-2, CO3-2=1.7x10E2,
F-=2x10E2 |
N-300 |
Liquid
Membrane |
Bromide
ion, combination
BR-2021 |
0.8
- 80K mg/l Br- |
5-6
pH / 50C |
S-2
must be absent, CN-,I-=10E-4, S2SO3-2, SCN-=10E0, Cl=10E2, NO3-, SO4-2,
CO3-2, F-=10E4 |
BR-200 |
Solid
Membrane |
Iodide
ion, combination
I-2021 |
0.01
- 127K mg/l I- |
5-6
pH / 50C |
S-2
must be absent, CN-=10E0, S2SO3-2=10E1, SCN-=10E3, Br=104, NO3, CO3-2,
PO4-3, Cl-, F-=10E5 |
I-200 |
Solid
Membrane |
Cadmium
ion, combination
CA-2021 |
0.01
- 1120 mg/l Cd+2 |
5-6
pH / 50C |
Hg+2,
Ag+2, CU+2 must be absent, Pb+2, Fe+3=10E0, CR+3=10E2, Na+, K+, Mg+2,
CA+2, Zn+2, Al+3=10E5 |
CD-200 |
Solid
Membrane |
|
Copper ion,
combination
CU-2021
|
0.06
to 630 mg/l Cu+2 |
5-6
pH / 50C |
Hg+2,
Ag+2 must be absent, Fe+3=10E-1, Al+3=10E1, CR+3=10E2, Na+, K+, Mg+2,
CA+2, Zn+2, Al+3=10E5 |
CU-200 |
Solid
Membrane |
Silver
ion, combination
AG-2021 |
0.1
to 108K mg/l Ag+ |
5-6
pH / 50C |
Hg+2
must be absent, Mg+2=10E3, CA+2, CU+2, Pb+2, Cd+2, Zn+2=10E4, Na+,
K+=10E6 |
AG-200 |
Solid
Membrane |
Sulfide
ion, combination
S-2021 |
0.3
- 32K mg/l S-2 |
>13
pH |
--- |
S-200 |
Solid
Membrane |
| Ammonium
Electrode (membrane type) AE-2041 |
0.09
- 1800 mg/l NH4+ |
>12
pH / 50C |
volatile
amines |
AE-Film |
AE-2041
(Set of 10) |
| Carbon
Dioxide (membrane type) CE-2041 |
Dissolved
gas:
1.49 to 1490mg/l
|
-
/ 50C |
Dissolved
gas: volatile weak acid
Atmosphere: Acidic gas |
CTC-211
Diaphragm cartridge |
CE-2041
(set of 4) |
Notes on ion electrodes::
Selective coefficient: 10Ex denoted that a concentration of interfering
ion in the sample soluton, that is greater than that of measured ion will
give the same meter indication.
When coexisting ions
are at a concentration that will affect the measurement value, solution
pretreatment will be required to prevent or minimize interference.
The Combined ion electrodes
are not designed as water proof sensors and are not built with temperature
probes included.
|