The SAT-500 salt
/ chloride analyzer is designed to measure the concentration of salt and
chloride ions quickly and easily in all types of products and where low
level chloride measurement is required. It
is an extremely helpful tool in the busy QA/QC lab or where high accuracy
and quick analysis time is required.
Features:
- Typical measurement
time is under 30 seconds.
- Extremely accurate.
- Absolute
method. No silver nitrate reagent is used. titrant standardization is
not necessary.
- Simply dispense the sample with a pipette into the measuring cell. Measurement
begins automatically.
- Built in printer
- Direct concentration displayed on instrument display.
- Data memory for 300 results
- Optional PC software is available for spreadsheet data control/archive
- Dilution ration and sample size are settable
Measuring Principle:
The SAT-500 is a dedicated
coulometric titrator for chloride. Silver is stripped from the cathode,
a pure silver wire, via an electrical current. By incorporating Coulombs
law, very low levels of silver can be generated which in turn complex
with the chloride in solution from the sample. The solution potential
is monitored with a silver wire and reference electrode sensing system
to determine the end point of the reaction, the point at which all the
chloride ions have complexed with silver, forming a silver chloride precipitate.
The instrument calculates
the concentration and the results are automatically displayed and printed
out in %(w/v), %(w/w), mg/l, or mol/l as NaCl or Cl (selectable).
Specifications:
| Measuring Range
and resolution |
2ul pipette:
0.01 - 49.99% (+/- 0.01%)
20ul pipette: 0.001 to 4.999% (+/- 0.001%)
200ul pipette: 0.0001 to 0.4999% (+/- 0.0001%)
Other: 0.000 to 99.99% (depends on calibration solution concentration)
|
| Lower limit |
0.02% at 200ul
sample
0.2% at 20 ul sample
2.0% at 2ul sample |
| Repeatability |
less than 0.5%
in c.v. value at 1% of NaCl standard solution with 20ul pipette |
| Calculation constant |
Possible to set
dilution ratio, constants, ec. |
| Calibration |
Automatic single
point calibration using standard NaCl solution |
| Measurement Start |
Automatic start
on detection of potential change or manual start using key |
| Printer |
Built in thermal
printer |
| Data Memory |
300 data points
(with backup) |
| Outputs |
RS-232C (for
PC or Ext. Printer)
Output 1 (for auto injector)
Output 2 (for Sample Changer)
|
| Power source |
AC line, 100-240V,
50/60 Hz |
| Power Consumption |
Approx. 20VA
(Max) |
| Dimensions (mm) |
Main: 190(w)
x 192(h) x 385(d)
Measuring section: 110(w) x 370(h) x 220 (d) |
| Weight |
Main: 3.3Kg,
Meas. section: 1.1Kg |
Main Unit
| SAT-500-0-2-B-0-B |
Salt analyzer complete with all standard accessories |
Standard Accessories for
the SAT-500
| Part
Number |
Description |
|
| AG-111 |
Silver Electrode |
(2
pcs.) |
| SAT-AG |
Silver wire for electrolysis |
(1
pce.) |
| ELR-003 |
Reference Electrode |
(1
pce.) |
| 6784580K |
reference
junctions |
(2
pcs) |
| SAT-1F1 |
Electrolyte |
500
mls. |
| SAT-1G1
|
Addition
Reagent, Gelatin |
50
mls. |
| SAT-1Z1 |
Polishing compound |
50
mls. |
| SAT-1E1 |
Reference electrode filling solution (potassium sulfate) |
100
mls. |
| SAT-B20 |
measuring
cell, 20 ml capacity |
(2
pcs.) |
| SAT-SB |
Stirrer |
1
unit |
| SAT-1A1 |
10% NaCl standard Solution (for 2ul syringe) |
100
mls. |
| SAT-1A2 |
1% NaCl standard Solution (for 20ul syringe |
100
mls. |
| SAT-SB |
Stir Bar (5 x 17mm) |
(2
pcs.) |
| PAP-HCS |
Thermal
Printer Paper |
5
rolls/pack |
| HEX-ACL3 |
power
cord |
|
| SAT-INST |
Instruction
Manual |
1
copy |
Micro dispenser
selection (optional)
| Part
Number |
Description |
Measuring
Range |
Recommended
Std solution |
| AIC-TC-259 |
Absolute pipette, setable to 1,2,3,4, and 5ul settings |
|
SAT-1A1
(10% NaCl) |
| AIC-TC-171 |
Absolute
pipette, setable to 10, 15, 20, 25, and 30ul settings |
Most
recommended |
SAT-1A2
(1% NaCl) |
| AIC-TC-184 |
Absolute
pipette, setable to 200,250,300,400,and 500ul settings |
|
|
| AIC-TC-197 |
Capillaries,
Teflon, P/P, and S.S. for AIC-TC-259 pipette, qty. 5 pcs. |
|
|
| AIC-TC-374 |
Capillaries,
P/P, and S.S. for AIC-TC-171 pipette, qty. 48 pcs. |
|
|
| AIC-TC-376 |
Capillaries,
P/P, and S.S. for AIC-TC-184 pipette, qty. 48 pcs. |
|
|
| AIC-TC-176 |
Pistons,
HPDE for AIC-TC-171 pipette, qty 5 pcs. |
|
|
| AIC-TC-186 |
Pistons,
teflon for AIC-TC-186 pipette, qty 5 pcs. |
|
|
| AIC-TC-732 |
Plunger/Piston
Wires for AIC-TC-259 Pipette, qty. 1 pce. |
|
|
| AIC-TC-734 |
Plunger/Piston
Wires for AIC-TC-171 Pipette, qty. 1 pce. |
|
|
| AIC-TC-736 |
Plunger/Piston
Wires for AIC-TC-184 Pipette, qty. 1 pce. |
|
|
| AIC-TC-701 |
Repair
Kit: Plunger springs, handle screws, service wrench, and snap ring |
|
|
| AIC-TC-227 |
Storage
Stand: Universal size holds four pipettes |
|
|
|
|
|
|
| OSZ00018 |
2ul Micro glass pipette dispenser |
0.00
- 49.99% |
SAT-1A1
(10% NaCl) |
| OSZ00021 |
20ul Micro glass pipette dispenser |
0.000
- 4.999% |
SAT-1A2
(1% NaCl) |
| OSZ00024 |
200ul Micro glass pipette dispenser |
0.0000
- 0.4999% |
by
dilution of std solution |
| OSZ00019 |
capillary for 2ul dispenser, glass |
|
100pcs/box |
| OSZ00020 |
Replacement parts kit, 2ul |
|
kit |
| OSZ00022 |
capillary for 20ul dispenser, glass |
|
100pcs/box |
| OSZ00023 |
Replacement parts kit, 20ul |
|
kit |
| OSZ00025 |
capillary for 200ul dispenser, glass |
|
100pcs/box |
| OSZ00026 |
Replacement parts kit, 200ul |
|
kit |
Options selection
| Part
Number |
Description |
| EPS-G
-0 |
External Printer Unit |
| OGC00003 |
Cable
for EPS-G external printer |
| P000119 |
Paper
for EPS-G external printer |
| ORD00001 |
Ink
Ribbon cartridge for External printer unit |
| G-LOG-2 |
Data
Logging software |
| OGC00002 |
RS-232
Cable, 2m |
|