The TTT-510 is an automatic sample processing unit for titration, pH, ion and conductivity automation. This fully automated system allows for the automatic processing of either 12, 18, 36, or 60 samples and incorporates an external electrode wash station for aqueous and solvent electrode conditioning. The TTT-510 is completely programmable and allows for multiple sequences.

ttt-510 sampler

Features
-Interface to a titrator, pH meter, ion meter or conductivity meter.
-Manual, automatic and computer controlled via RS-232 interface.
-Complete sequence timing and rinsing control.
-External electrode wash station.
-Uses standard size beakers. 12 position is standard
-Removable sample turntable.


 

Specifications
Number of beakers 12, 18, 36, or 60 (specify when ordering)
Size of beakers 200 ml or 300ml tall for 12 position
100 ml tall for 18 position
30 ml or 50 ml tall for 32 position
20 ml for 60 position
Electrode cleaning Aqueous and non-aqueous
Alarm End detection, buzzer & lamp alarm of cleaning solvent
Setting of cleaning method Water and solvent reagent valve (specify)
Cleaning time setting 0 to 9999 seconds (Wash Timer)
Setting electrode dip 0 to 9999 seconds (Water Timer)
Stability time setting settable
Power source AC line, 50/60 Hz
Dimensions/Weight 405mm (W) x 320mm (H) x 570mm (D), 21kgs
Interface to models AUT-501 titrator

 

Main Unit
TTT-510-1-3-1 for 12 sample beakers, AC115V
TTT-510-1-3-2 for 18 sample beakers, AC115V
TTT-510-1-3-3 for 36 sample beakers, AC115V
TTT-510-1-3-4 for 60 sample beakers, AC115V
TTT-510-1-3-5 for 100 sample beakers, AC115V (Special order only)

Standard Accessories
See Table Plate info 12, 18, 36, or 60 position turntable 1 Pce
See Electrode Cartridge info Electrode cartridge ! Pce
TTT-P001-C Polyethylene tank for cleaning 1 Pce
TTT-P001-W Polyethylene tank for waste water 1 Pce
TTT-P003 Float switch for waste water 1 Pce
TTT-P004 Float switch for pure water 1 Pce
TTT-P005 Waste Water Hose 1 Pce
TTT-P006 Rinse Water Hose 1 Pce
End Pin 1 Pce
Operation manual 1 Pce
HEX-ACL3 Power cord 1 Pce

Automatic Sampler Configuration:

TTT-510-12 Automatic turntable unit, 12 samples.(uses 200 or 300ml tall beakers) Rec. 8x30mm stir bar
TTT-510-18 Automatic turntable unit, 18 samples.(uses 100ml tall beakers) Rec. 8x30mm stir bar
TTT-510-32 Automatic turntable unit, 36 samples.(uses 50ml tall beakers) Rec. 8x25mm stir bar
TTT-510-60 Automatic turntable unit, 60 samples.(uses 20ml Cell) Rec. 5x15mm stir bar
OGC00005 AUT-501 to TTT-510 Connection Cable, 1m(std), 2m, 4m, 10m avail.  
P000023 Air Pump for forced air cleaning  
P000020 Waste Water Valve (pinch cock) for bubbling cleaning  
P000021 Waste Water Valve, electric magnetic, for bubbling cleaning  
Air Pump for Bubbling  
P000022 Non-Aqueous chemical feed pump for chemical cleaning  
P000032 Propeller Stirrer motor, Over head type  

TTT-31012 for 12 sample beakers
TTT-31018 for 18 sample beakers
TTT-31036 for 36 sample beakers
TTT-31060 for 60 sample beakers
Table Plate and Electrode Holder Cartridges
S-ECT-12 for 12,18 sample beakers
V-ECT-24A for 36 sample beakers
S-ECT-24B for 36 sample beakers
S-ECT-25C for 36 sample beakers
V-ECT-36 for 60 sample beakers
-1 1 channel cartridge Used for all table sizes
-2 1 channel cartridge for 12,18, 36 sample beakers
-3 2 channel cartridge for 12,18, 36 sample beakers
-4 2 channel cartridge for 12,18, 36 sample beakers
-5 2 channel cartridge for 12,18 sample beakers
Multi cartridge for 12 sample beakers
for sample suction Used for all table sizes


Note: 1) If using S-ECT-24C(2CH-2) or S-ECT-36(1 CH-1) for titration, it is recommended to use trace volume titration nozzle AST-P008 instead of normal titration nozzle.
2) Depending on sample and required analysis items, different type of cleaning method is recommended for continuous measurement.

Connection Cables:

OGC00005 AUT-501 to TTT-510 Connection Cable, 1m(std)
OGC00006 AUT-501 to TTT-510 Connection Cable, 2m
OGC00007 AUT-501 to TTT-510 Connection Cable, 4m
OGC00008 AUT-501 to TTT-510 Connection Cable, 10m

Electrode Extension Cables by electrode type:

5000HN1M GS-5000 Series (1m length)
5000HN3M GS-5000 Series (3m length)
5000HN5M GS-5000 Series (5m length)
5200HN1M GS-5200 Series (1m length)
5200HN3M GS-5200 Series (3m length)
5200HN5M GS-5200 Series (5m length)
5300HN1M GS-5300 Series (1m length)
5300HN3M GS-5300 Series (3m length)
5300HN5M GS-5300 Series (5m length)
5400HN1M GS-5400 Series (1m length)
5400HN3M GS-5400 Series (3m length)
5400HN5M GS-5400 Series (5m length)
5700HN1M GS-5700 Series (1m length)
5700HN3M GS-5700 Series (3m length)
5700HN5M GS-5700 Series (5m length)
5700HN10M GS-5700 Series (10m length)

 

 

 